RS4.DIN.406.24V SIL4 safety relay

The 406 vital relay features 4 NO contacts SIL4-guaranteed to open and 6 NC contacts.

RS4 safety relays feature Normally Open (NO) contacts guaranteed on opening with the highest safety level, SIL4, and Normally Close (NC) contacts. These contacts are weld no transfer, compliant with EN 61810-3 Type A (forced guided contacts). They are available in several command voltages, mounting interfaces and NO and NC contacts configurations.

Certified EN 50155, RS4 vital relays are suited for train on-board applications.

The vital RS4.DIN.406.24V can be used on board or track side for signaling projects. The safety relay features 2 inputs to take into account the wire impedance connected between the relay command and the relay. The safety relay provides 4 NO contacts guaranty on opening with a SIL4-level and 6 NC contacts.

One safety relay is also available in 3U-card format with two independent 202 relays. This safety relay version provides 4 NO contacts guaranty on opening with a SIL4-level and 4 NC contacts.

For on board application the new RS4.DIN.202.110V, certified EN 50155, features 2 NO contacts guaranty on opening with a SIL4-level and 2 NC contacts. Its command voltage input is 110VDC.

For trackside application, like signalling project, theRS4 safety relays (except the 110V version)  feature two voltage inputs to accommodate the impedance of the connection between the command of the RS4 safety relay and the RS4 safety relay: 0 to 18Ω and 18 to 45Ω.

This double input allows to use the safety relays in post or in line with the same relay reference (except the 304 which has two references).

Document, ISA* certification and trademark

Download datasheet

RS4 is a registered trademark. It is also registered in China:

  • KE AN SI – 科安思
  • JI AN SHI – 继安世

CLEARSY is the direct distributor of the products.

Technical features

  • It integrates two PCB relays which meet DIN EN 61810-3standard (forcibly guided relay).
  • The two PCB relays are coming from different series to protect against the shared modes introduced by manufacturing errors involving a single series.
  • Two “working” contacts from each PCB relay are twisted in series to work out the security output. The distances between the internal tracks and the pins of the safety control must respect the NF F 74003 standard to guarantee the absence of a short circuit.
  • The distances between the control of the PCB relays and the security output strips must resist to insulation tensions of 2000Vac.
  • The circuit safety is processed with a SIL4 safety level

Need a custom-made system ?

We are safety software and systems designers.  Contact us and let's discuss your project together!